Warning: mkdir(): No space left on device in /www/wwwroot/173.82.90.42/func.php on line 127

Warning: file_put_contents(./cachefile_yuan/wenxinxueba.com/cache/4f/6b452/875ce.html): failed to open stream: No such file or directory in /www/wwwroot/173.82.90.42/func.php on line 115
Mouse MCP-2 (Monocyte Chemotactic Protein 2) CLIA Kit (STJC0001367) STJC0001367|產品目錄|代理商|上海91麻豆福利视频网生物科技有限公司
產品詳情
  • 產品名稱:Mouse MCP-2 (Monocyte Chemotactic Protein 2) CLIA Kit (STJC0001367)

  • 產品型號:STJC0001367
  • 產品廠商:ST john's laboratory
  • 產品文檔:
你添加了1件商品 查看購物車
簡單介紹:
Mouse MCP-2 (Monocyte Chemotactic Protein 2) CLIA Kit (STJC0001367)
詳情介紹:
Applications: CLIA
Reactivity: Mouse
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 1.88pg/mL
Detection Limit: 3.13~200pg/mL
Short Description: This mouse MCP-2 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence
Specificity: This kit recognizes Mouse MCP-2 in samples. No significant cross-reactivity or interference between Mouse MCP-2 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids
Specificity This kit recognizes Mouse MCP-2/CCL8 in samples. No significant cross-reactivity or interference between Mouse MCP-2/CCL8 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 87-102 94
EDTA plasma(n=8) 95-106 100
Cell culture media(n=8) 96-112 102

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 9.22 30.22 69.59 8.47 32.01 66.32
Standard deviation 1.13 2.40 5.54 0.76 2.89 4.21
CV (%) 12.26 7.94 7.96 8.97 9.03 6.35
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance
姓名:
電話:
您的需求:
 
網站地圖